IXcellerate Moscow
North campus

0
Data centers
10000
Campus size
1MW
IT load
1+
Telecom operators

IXcellerate Moscow North campus is a multi-venue commercial data center facility built to serve the ever-growing demand for colocation on the Russian Internet market. Located within Moscow metro area, IXcellerate North comprises three data centers – MOS1, MOS2 and MOS3, with a total power capacity of 54 MW (once fully developed). All data centers are designed to accommodate high-load servers and infrastructure for ultra high power density computing in accordance with the Tier III / Level 3 reliability level, granting 99,999% SLA.

Since the launch of our first data hall in 2013, our customers have grown to recognize IXcellerate as a data center operator who puts  customer’s needs first. Our reliable infrastructure with customizable cooling and power solutions, as well as outstanding connectivity and security options are consistent across all three data centers – all backed by our operational track record and meticulous adherence to international standards and practices.

MOS1

MOS1

Moscow One data centre (MOS1) is a Tier III/Level 3 facility and has three data halls to house 1835 racks across 6000m², with a total power capacity of 13.7 MW, supplied via diverse roots from city grid.

Highly secured and fault-tolerant, all IXcellerate Moscow North facilities are carrier-neutral and provide easy access to more than 50 Tier I and Tier II carriers, as well as to 35+ clouds and IX platforms.

  • Total capacity: 13.7 MW, 1835 racks
  • Useful space: 6000 m²
  • PCI DSS and ISO certificates
  • 24/7/365 technical support in English and Russian
  • Warehousing options
  • Power availability SLA: 99.999%
  • Design PUE: <1.6
  • UPS redundancy: 2N
  • Centralized N+1 standby diesel generators
  • Batteries: lithium-ion units to support 10 min at full load
  • Power density per rack – up to 20 KW
  • Highly efficient, customizable cooling systems
  • Cooling redundancy: N+1
  • Chillers enhanced by adiabatic cooling
  • Containment: cold and hot aisles
  • Guaranteed climate in accordance with ASHRAE
  • Up to 6 levels of physical security
  • 24/7 dedicated onsite security team
  • Non-contact biometric access system
  • CCTV with motion detectors
  • Airlocks, speed stiles, mantraps
  • Strict access and authorization policies & procedures
  • Over 50 telecom operators with high-speed Internet access and low latency
  • Multiple independent fiber Points of Entry
  • Inter- and intra-campus connections
  • Meet-Me-Rooms
  • Access to multiple IX platforms, including Eurasia Peering and MSK-IX

MOS2

MOS2

Moscow Two (MOS2) data center is a Tier III facility that accommodates 1580 racks across 3,300 m² with a total power capacity of 13 MW.

Highly-secured and fault-proof, all IXcellerate Moscow North facilities are carrier-neutral and provide easy access to more than 50 Tier I and Tier II carriers, as well as to 35+ cloud and IX platforms.

  • Total project capacity: 12 MW, 1580 racks
  • White space: 3300 м²
  • Tier III, PCI DSS and ISO certified
  • 24/7/365 technical support in English and Russian
  • Warehousing options
  • Power availability SLA: 99.999%
  • Design PUE: <1.5
  • UPS redundancy: 2N
  • Centralized N+1 standby diesel generators
  • Batteries: lithium-ion units to support 10 min at full load
  • Power density per rack – up to 35 KW
  • High-efficiency, customizable cooling systems
  • Cooling redundancy: N+1
  • Precision-based Vertiv PDX chillers with EconoPhase™
  • Containment: cold and hot aisles
  • Guaranteed climate in accordance with ASHRAE
  • Up to 6 levels of physical security
  • 24/7 dedicated onsite security team
  • Non-contact biometric access system
  • CCTV with motion detectors
  • Airlocks, speed stiles, mantraps
  • Strict access and authorization policies and procedures
  • Over 50 telecom operators with high-speed Internet access and low latency
  • Multiple independent fiber Points of Entry
  • Inter- and intra-campus connections
  • Meet-me-rooms
  • Access to multiple IX platforms, including Eurasia Peering and MSK-IX

MOS3

MOS3

Moscow Three (MOS3) is a brand new data center launching in Q1 2022. As a part of IXcellerate North Campus, it is designed to accommodate high-power, high-density installation across 12,000m² total area, fit to house >2000 racks with total power capacity of 25 MW.

Highly-secured and fault-proof, all IXcellerate Moscow North facilities are carrier-neutral and provide easy access to more than 50 Tier I and Tier II carriers, as well as to 35+ cloud and IX platforms.

  • 12,000 m2 total area
  • Rack space capacity: 2,000+
  • IT load: 16 MW
  • Total power: 25 MW
  • Design PUE at full load: <1.25
  • Designed for high-power, high-density computing
  • On-demand power and cooling solutions
  • Technical support 24/7/365 in Russian and English

We're ready to answer all your questions